Category : Test Equipment :   Testing Set and Module : Agilent 85110A Option H60 2-50GHz Pulsed-RF Microwave S-Parameter Test Set (85110A)

85110A

See photos

Product Details

Agilent 85110A Option H60 2-50GHz Pulsed-RF Microwave S-Parameter Test Set  (85110A)

Unit Price      Contact Sales
Your Price Contact Sales
Item# CLN001833
Manufacturer Agilent
Mfg. Part# 85110A
Condition Used
Unit Of Measure each
Dimension
Weight

Agilent 85110A Option H60 2-50GHz Pulsed-RF Microwave S-Parameter Test Set  (85110A)

   

Product Outline

The Agilent 85110A Option H60 Test Set is 2 to 50 GHz mixer-based S-parameter test set. Vendor supports until April 1, 2009.

 

The Agilent 85110A test set is specially configured for operation in pulsed-RF measurement systems. Four 90 dB step attenuators protect each input of the fundamentally-mixed down converter to allow measurement of test devices with output power of 20 W CW. Special test set options are available from 0.5 to 20 GHz and 2 to 50 GHz. This test set is Agilent 85110A Option H60 that is 2 to 50 GHz mixer-based S-parameter test set.

 

Test sets 85110A Option H60 and Option H61 are identical except for the placement of the path links. Path links refer to the links from P1 RF OUT to P1 RF IN and from P2 RF OUT to P2 RF IN. Devices such as amplifiers and isolators can be inserted in place of the path links to optimize system performance. Path links are located on the rear panel for the 85110A Option H60, and on the front panel for the Option H61.

 

The Agilent 85110A Option H60 50 GHz mixer-based S-parameter test set may be used together in Agilent 8510C with RF source: Agilent 83650B, 50 GHz synthesized sweeper; LO source: Agilent 83620B, 20 GHz synthesized sweeper; Calibration kit: Agilent 85056A, 2.4 mm calibration kit.

Key Features:

·         2 to 50 GHz frequency range

·         For use in pulsed-RF measurement systems

·         Measurement of devices with 20 W CW output power



click here for manufacturer specification 






Specifications










More details






Frequency Range 2 to 50 GHz
Nominal Operating Power Level 0 to -3 dBm
Connector Type 3.5 mm, male
Impedance, DC Bias 50 ohm nominal, 500 mA, 40 Vdc maximum
Attenuation Range (Incident Signal) 0 to 90 dB, in 10 dB steps
RF Input Connector (Rear Panel) Maximum Input Power: +14 dBm
Receiver Dynamic Range (dB) Pulsed: 75 74 73; CW: 89 89 88
System Dynamic Range (dB) Pulsed: 64 62 60; CW: 78 77 75
Equivalent Measurement Bandwidth (-3 dB) 1.5 MHz
Transition Time (10% to 90%) 300 ns
Trigger Level TTL (falling edge), external
Trigger Width 100 ns, minimum
Aperature Uncertainty <1 ns, typical
Minimum Time Display 5 microseconds
Maximum Time Display 40 ms